Name |
Formats and permitted characters |
DP-Identcode
|
Formats: nn.nnnnnn.nnn, nn.nnnnn.nnnn, nn.nnnn.nnnnn, nn.nnn.nnnnnn Permitted characters: [0-9] A code is (9*number of characters+9) bar widths wide. Width: 32.0 mm - 585 mm (at least 5 mm light zone right and left). Height: 25 mm. Check digit is calculated automatically; relation: 4:9; special 2 of 5 IL code. |
DP-Leitcode
|
Format: nnnnn.nnn.nnn.nn Permitted characters: [0-9] A code is (9*number of characters+9) bar widths wide. Width: 37.25 mm - 67-5 mm (at least 5 mm light zone right and left). Height: 25 mm. Check digit is calculated automatically; relation: 4:9; special 2 of 5 IL code. |
FIM
|
Formats: A, B, C Permitted characters: [A-C] Minimum size: 1/2" * 5/8". The FIM barcode is always printed in the size specified by the US Postal Office. This means that it might extend beyond the available object border. |
German Parcel |
Format: any, must have an even number of characters. Permitted characters: [0-9] A code is (14*number of characters+18) bar widths wide. Relation: 1:2 |
Japanese Postcode |
Japanese Postcode. Format: Postcode as nnn-nnnn, then max. 13 character address Permitted characters: n=[0-9], address=[A-Z], [0-9], [-] |
Maxicode
|
Can display all available and non-printable characters. Note the options dialog. In order to enter non-printable characters (binary data) in the barcode text, they must be packaged in a special string. The data is inserted using the "{binary:nn}" string, whereby nn stands for any sequence of two-character hexadecimal numbers. This is especially important if Maxicodes are to be created according to UPS specifications; the special characters needed for this can be entered in this way. Example: in order to pack a Null and a Backspace (BS) character in the data, use "{binary:0008}" (corresponds to "{binary:00}{binary:08}"). Example: use "Hallo{binary:0d0a}world" to include a line break. |
Maxicode/UPS
|
Format: Formatting according to UPS specifications. Note the options dialog. Permitted characters: all characters |
Postnet
|
Formats: nnnnn, nnnnn-nnnn, nnnnn-nnnnnn Permitted characters: [0-9] Minimum size: 1.245" * 4/16" (10-digits). Bar distance at least 1/24". Error correction digit will be appended automatically. This bar code is automatically printed in the right size if the object is larger than the maximum size of the barcode. |
Premiumadress
|
Mail Barcode of Deutsche Post (German postal services). Format: According to DPAG specifications. Note the options dialog. Permitted characters: According to DPAG specifications. |
RM4SCC, KIX® Royal Mail with CRC
|
Permitted characters: [A-Z], [0-9], [a-z] Permitted characters: [A-Z], [0-9], [a-z] Format: Either just the post code is coded (e.g. LU17 8XE) or the post code with a supplementary "Delivery Point" (e.g. LU17 8XE 2B). The maximum number of characters that can be used is therefore limited to 9. |